Training frequency for educating schoolchildren in basic life support: very brief 4-month rolling-refreshers versus annual retraining—a 2-year prospective longitudinal trial
Abelairas-Gómez, C., Martinez-Isasi, S., Barcala-Furelos, R., Varela-Casal, C., Carballo-Fazanes, A., Pichel-López, M., Fernández Méndez, F., Otero-Agra, M., Sanchez Santos, L., & Rodriguez-Nuñez, A. · 2021
Current published assessment
Assessment status: One paper reading is stored
The published assessment remains the archive’s current judgment. Stored model readings are preserved separately and never replace it automatically.
Bottom line
Current archive record
At a two-year test, Spanish children initially aged 8 to 12 completed the emergency-response sequence most often after refreshers every four months, next after one annual retraining, and least often with no retraining. The refresher group also led on some chest-compression measures, but CPR quality was low in every group. Each schedule was used in just one school, so the study cannot separate the schedule from differences between schools.
Read the full explanation
What was found
Children who got refreshers every four months completed the basic life support sequence more often at two years than children retrained once at one year. The annually retrained group in turn did better than children who got no retraining. Basic life support here means the emergency steps a bystander takes when someone collapses, ending with chest compressions (CPR). Each schedule belonged to a different school, so the results cannot establish that the schedule caused the differences.
The clearest result is the full six-step sequence, such as checking that the scene is safe, checking whether the person responds and calling emergency services. At two years, the share of children who got every step right was:1
- no retraining: 0 of 146 (0%);
- one retraining at one year: 28 of 124 (22.6%);
- refreshers every four months: 88 of 202 (43.6%).
The paper's statistical tests found a difference between every pair of groups, subject to the school-comparison limits below.
Between the first test and two years later, the no-retraining group got worse on every step except starting CPR. The once-a-year group got worse on checking safety, checking response, opening the airway and checking breathing. The refresher group did not change, and it was the only group with at least 70% correct on every step. At two years, it beat the once-a-year group on checking safety, checking response, opening the airway and calling emergency services.2
Chest compressions were weak in every group
The quality of CPR was low in all three groups, though the refresher group came out ahead on some measures. A training manikin scored each child over two minutes of compressions. The percentages below are averages across children. Whenever three numbers appear, the order is no retraining, annual retraining, then four-month refreshers.
- Overall CPR quality score: no retraining 16.4%, once a year 25.3%, refreshers 29.9%. These are the manikin's percentage scores, not percentages of children passing. The record does not explain how the overall score is calculated. The refresher group beat both other groups; the annual and no-retraining groups did not differ significantly.3
- How deep the compressions went: on average 31.3, 33.5 and 36.7 mm, against a target of 50 to 60 mm. The refresher group pushed deeper than both other groups.4 Only 6.2%, 8.1% and 12.4% of children reached an average depth of 50 mm.
- Share of compressions at the correct depth: 7.2%, 10.8% and 15.5%. The refresher group beat both other groups.5
- Hand position: correct on 76.4% of compressions with no retraining, against 92.5% and 95.0% in the two retrained groups. Both retrained groups beat no retraining, but did not differ significantly from each other.6 The no-retraining group had been at 97% right after the lesson.
- Speed of compressions and letting the chest rise fully: the tests found no significant differences between groups. This does not establish that the groups were identical.7
What limits the conclusion
The study cannot separate the refresher schedule from the school a child attended. Three schools took part, and each school was randomly assigned to one schedule. The lottery decided which school followed which schedule; it did not remove differences between their teachers or pupils. With only one school per schedule, there was no second school on the same schedule to help distinguish school differences from schedule effects. The first post-lesson test gives a reference for later change, but this remains a comparison that cannot isolate the effect of refresher frequency.
The statistical tests treated children as separate observations, without accounting for their shared school. The tests count hundreds of children, even though only three schools were independently assigned. Their p-values do not capture uncertainty about differences between schools, so they cannot establish that the schedule explains a difference. No school-level adjustment was possible with one school per schedule.
The groups were also not equal at the first post-lesson test. The once-a-year group already had a much higher overall CPR quality score (26.8%) than the no-retraining group (12.8%) and the refresher group (10.8%). So the refresher group's lead at two years reflects it rising from the lowest start, from 10.8% to 29.9%, while the once-a-year group stayed flat, from 26.8% to 25.3%.3
Other limits:
- The refresher group had practiced about 4 months before the final test; the once-a-year group about 12 months before. The comparison mixes how often children practiced with how recently.
- Of 658 children invited, 472 were analyzed and 186 (28%, or 28.3% before rounding) were left out for missed sessions or tests, missing consent or logistics. Exclusions were not broken down by group or reason, and schools that missed sessions were dropped.
- The testers were instructors from the research team. The paper does not say whether they were kept unaware of each child's group. They also prompted children who did not start CPR or call emergency services.
- The six-step sequence used the research team's own checklist, based on European Resuscitation Council guidance from 2015. The CPR measures came from a standardized manikin, independent of that checklist.
- The study was not registered in advance and had no calculation of how many children it needed. It tested many outcomes without adjusting its statistical threshold for doing so; more tests create more opportunities for chance findings to look convincing.
- The study was run by the group that designed the program. Its authors also wrote another trial of school CPR materials, so the two results are not independent of each other. Whether this school trial has been replicated was not assessed. Refresher studies in healthcare staff concern a different population and question.
- No one checked whether teachers delivered the lessons as planned, and results were not broken down by age.
- Body measurements were reported as similar across groups, but there were no data on family circumstances or earlier academic attainment to compare school intakes.8
Who and what were compared
The children were 8 to 12 years old initially, in grades 3 to 6 at three city schools in Spain, and about two years older at the final test. The schools were a convenience sample, not randomly selected; the city was not named. All children first had the same 100-minute lesson: two 50-minute physical education classes in one week, taught by PE teachers who had had 2 hours of training from the researchers.9 After that:
- one school got no further training;
- one school got a single 50-minute, mostly hands-on retraining at one year;
- one school got five 5-minute refreshers, one every four months. Five minutes described the brief practice, but each refresher occupied a full 50-minute class because there were only three manikins. That was the classroom time used in this study.
Children were tested individually within a week of the first lesson and again two years later, in a staged scene where a manikin stood in for their collapsed PE teacher. Compressions were measured on a Laerdal Resusci Anne QCPR manikin, with targets of 50–60 mm depth and 100–120 compressions a minute.
The full seven-page published paper supports this account, with the limits on checking described below.10
Footnotes
-
Counts at the two-year test. A p-value describes how unusual results at least this far apart would be under a statistical model with no difference between groups. Here p < 0.001 for each pair: no retraining vs once a year, no retraining vs refreshers, and once a year vs refreshers. It does not give the probability that the schedule caused the difference, and it does not remove the school-comparison problem. No confidence intervals, which describe the precision of an estimate, are reported for the complete-sequence result. ↩
-
The step-by-step results appear only in Figures 2 and 3 as graphs with one spoke for each step, called radar charts; no table gives the values. Exact percentages were not extracted or checked numerically from these graphs. Declines in the no-retraining group had p < 0.05, several with p < 0.001. ↩
-
Values are averages, with standard deviations (SDs) in parentheses. SD describes how much individual scores vary around their group's average, not how certain the average is. Unless otherwise labeled, all triples follow the order no retraining, annual retraining, four-month refreshers. Mean percent (SD) at two years: 16.4 (24.1), 25.3 (28.8), 29.9 (29.4). Refreshers vs no retraining p < 0.001; refreshers vs once a year p = 0.025; once a year vs no retraining not significant. At the first post-lesson test: 12.8 (22.3), 26.8 (29.2), 10.8 (18.6); the annual group was already higher than each other group, p < 0.001. ↩ ↩2
-
Mean (SD) in mm: 31.3 (10.9), 33.5 (10.8), 36.7 (11.5). Refreshers vs each other group p < 0.001. ↩
-
Mean (SD) percent: 7.2 (16.7), 10.8 (22.7), 15.5 (26.1). Refreshers vs no retraining p < 0.001; refreshers vs once a year p = 0.010. Right after the first lesson these were 3.9, 4.3 and 2.3. The paper's abstract misreports this result: it gives the no-retraining figure as 3.9 ± 11.8, which is that group's value right after the first lesson (at two years it was 7.2 ± 16.7), and labels the unit mm when it is percent. The figures used here follow Table 1. ↩
-
Mean (SD) percent: 76.4 (35.1), 92.5 (19.7), 95.0 (17.2). No retraining vs each retrained group p < 0.001; the two retrained groups did not differ significantly. Initial averages were 97.0%, 96.1% and 98.2%. The no-retraining group's fall from 97.0% was significant (p < 0.001). ↩
-
At two years, the average percentages of compressions at the correct rate were 34.9%, 39.8% and 38.8%; the percentages allowing full chest recoil were 89.4%, 86.2% and 84.8%. Neither measure showed significant differences between groups. ↩
-
Compression depth correlated with weight, height and body mass index (BMI). The CPR analyses adjusted for these body measurements where statistically significant. This does not account for unmeasured school-intake differences. ↩
-
Teacher training comprised 40 minutes of theory and 80 minutes of practice. The initial lessons included theory and 15-minute rotations through the response sequence, compression-only CPR on a basic torso, and compression-only CPR on a torso providing device feedback. There was one manikin per five pupils. Refreshers involved recalling the sequence in groups of five, then two minutes of CPR in groups of three. ↩
-
Read depth and number checking cover the full seven-page published version, including the tables and timetable; the step-level graphs were not checked numerically. The article references no supplement, its underlying data are available only on request, and prepublication peer-review files were not available for checking. The record's verification note also flags five follow-up-category labels as wrong, although its effect rows currently all say 1–2 years; the stated final test time is two years. Funding came from Instituto de Salud Carlos III PI20/01355, co-funded by FEDER, and an FPU fellowship; no competing interests were declared. ↩
Confidence interval
A confidence interval is the range of effect sizes consistent with the data — the study's honest statement of its own precision. "g = 0.30 [0.10, 0.50]" says the best estimate is 0.30, and values from 0.10 to 0.50 would all fit the evidence comfortably.
The interval matters more than the point estimate. An interval that includes zero means the study cannot rule out "no effect." A wide interval means a small study: "g = 0.6 [−0.1, 1.3]" sounds impressive and establishes almost nothing (see statistical power).
When this site reports a number in brackets after an effect, it is this interval.
Results
- Outcome
Complete BLS sequence performed correctly (all six steps; research-team instructor checklist per ERC 2015)
Result 1ResultCG 0/146 (0%); SG 28/124 (22.6%); RRG 88/202 (43.6%); p<0.001 for CG vs SG, CG vs RRG and SG vs RRG. No CIs; one school per arm
Reported as: number (%) of children per arm; child-level chi-square
Compared withactive-alternative
TimingT2, 2 years after initial training; ~4 months after RRG's last refresher, ~12 months after SG's retraining
Technical details
- Measure
- researcher-designed
- Measure origin
- developer-created
- Horizon
- 1-2yr
- Outcome class
How the study worked
The recorded sample, comparison, methods, and practical details.
Sample
Who or what was studied
How the study worked
How much confidence should we place in this?
Limits of the research itself, separate from checks on this interpretation.